Specifications
Work Mode: Continuous
Rated Voltage: 220V,50Hz
Rated Power: 3,000W
Net Weight: 350Kg
Size: L75*W250*H120cm.

*System Instructions

Part B- Facade of the Pre-Filtering System.

① Conductivity Probe,
② Filter-pressure Meter,
③ Precision Filter,
④⑤⑥ are C1, C2, C3’s inlet water valve to the electrolysis chamber.

Part C - Facade of the Electrolysis Chamber.

① Meter of acid water outlet of the first electrolysis chamber.
② Meter of alkaline water outlet of the first electrolysis chamber,
③ Meter of acid water outlet of the second electrolysis chamber,
④ Meter of alkaline water outlet of the second electrolysis chamber,
⑤ Meter of acid water outlet of the third electrolysis chamber,
⑥ Meter of alkaline water outlet of the first electrolysis chamber;
⑦,⑧,⑨,⑩,⑾, are the valves corresponding to ①,②,③,④,⑤,⑥.

Part D-Facade of the Electric Control System (ECS)

①Ammeter
②Power indicator
③Voltmeter
④PH&ORP
⑤ Knob to Change Voltage
⑥Conductivity Meter
⑦ Indicator light point A
⑧AB switch
⑨Indicator light point B
⑩Working indicator
⑾” Start Button” to start the system.
⑿”Stop Button”to stop the system.
⒀ Pump indicator light,
⒁ “Start Button” to the pump
⒂ “Stop Button” to the pump.

Part E: ECS Stucture

Part E: Inside of the electric control system. ①Air Switch ②fuse③Joint of the water level Signal④Power supply for the Pump⑤Power cord



Part A: Profile of the system
Part A: water –input profile.① Acid water output ②waste water output
③Valve of waste water④Alkaline water out put ⑤ tap water input ⑥ PH/ORP Tester
⑦Pressure -discharge ⑧ Magnetic valve for pressure discharge ⑨Air- discharge valve for the filtering

Installation

1. Prepare the water tank and the pump.
2. Tap water input connection
3. Connect the water tank and the plum to the system.

• A5 is the water inlet, which connects to the outlet of the pump.
• A4 is the outlet of the alkaline water
• A1 is the outlet of the acid water.
• A2 is the outlet of the waster water.

• The alkaline water is not very good when the system works 5 mintutes initially each time, and please turn on the A3 valve to discharge.

A7 is pressure discharge valve.
• If the water pressure is too high for the electrosis chamber, the A8 will turn on auto-matically and the water will be discharged by A7 outlet.

Attention:

• This system includes the control system of the water tank and the water pump, Make sure to prepare the water tank and the pump.
• If your requirement of alkaline water is not very high, you may not connect the A2 ( the waste water outlet); if you want to connect A2 to the pipe, the height of the A4 pipe shall be higher than A2’s location, otherwise, the waste water will not be discharged.

Electric Control System Connection

E 1 - Power supply cord of the whole system.
E3- Connection to the water level signal, connect the signal cord to the E3.
• For the installation of the signal switch, please refer to the instructions.
E4 - Joint to the pump,it connects the pump cord to the E4.









Special Test Instructions

Inspecting the System
• Check the voltage and the ground cord connection if correct
• Ensure that all related valves are turned on
• Place the D5 (Volt. Adj. )at the lowest
• Ensure tap water can meet the following requirements:
The PH is not less than 6.3
• The conductivity is between120us/cm to 30us/cm
• Working environment:
• Temprature: 5-40°C
• Humidity: ≦80%
• Inlet water temperature: 5-40°C
• Inlet water pressure: 0.1-0.25MPa
• Power supply: 220V/ 50A
• Ground cord is required, the resistance is 4Ω

How to start the System

1. After inspection, adjust the D5 as “0” and turn on the E1 ( air switch), the D2 will light up.
2. Press the “System Start” button, the D11&D10 will light up.
3. Turn on the inlet water valve and the pump, the D14&D13 will light up.
4. Turn D8 to Point A, for the meantime, reserve the flow meter and the D1 Am meter, then adjust the D5 voltage and the current can’t be over 150A.

When the flow rate is up to 3000 liters per hour, test the PH of the water, if it can meet the requirement, turn off the A2( the waste water –discharge valve).

If the desired pH level was met, it indicates that the system works properly.

How to Stop the System

1) Turn on A2 and adjust the D5 as “0”,then make the D8 in the middle.
2) Press D15 turn off the pump,then D13 light will be off.
3) press D12 to stop the system, then D10light will be off
4) Turn off the E1

During Operation
1. Follow the instructions strictly before operation。
2. While the system works about 4 hours, turn on A2 and adjust the voltage as “0” and discharge the waste water.
3. Then place the A8 to Point B and adjust the voltage to increase then turn off the A2.
4. After the system woks 4 hours at point B turn to A the same way, therefore 4 hours is a phase to point A &B.


Proper Maintenance
• Keep A-B working
• Keep the system clean
• Inspect the system frequently
• Extreme cold temperature protection needed
• Clean the system when not in use for several days.
• If it has not been used for long, please use the non-Aircompressor to blowdry
• Preserve the flow meter.
• Don’t turn off the flow valve completely
• The water press must not exceed beyond the proper work range

Common Situations

1. Alkaline and acid water inverts
What to do: Plug the wires inverts.

2. No variation of Voltage
What to do: Replace the Si PCB Board.

3. The fuse often burns
What to do: Replace the diode

4. There is only one pipe for the discharge water flow meter and the purified water flow meter
What to do: Replace the magnetic valve.

5. PH is not good after increasing the voltage
What to do: Replace the electrolysis chamber

Special Features
1. Can produce 3000Liters of water per hour
2. Can produce water pH level from 7.0 to 10.0
3. Safe and economical
4. Will make production faster
5. Can accommodate water from different sources

Price Range:
Technical Support Services
1.Water-con will provide all the necessary product information for better product knowledge.
2.Technical trainings are provided along with product research and development.
3.Warranty services are provided together with product demonstration and installation.
4. A technical support officer and technical installer are provided by Water-con.
5. Repair service centers and technicians are accessible to all clients.

Why is it beneficial?
1. I will no longer worry about the quality of water for all the customers of my hotel.
2. I don’t need to spend more time boiling water for my little kids.
3. The production of our cosmetic products is safe and easy.
4. I am worry-free about the water we are using on my restaurant.
5. My customers will stay with us for having the healthy and safest water.

*System Instructions adapted from EHM Group Ltd, E-Heath Manufacturer

No comments: